Measuring temperature and current of SP7021 for many cases

1. Firmware setting:

File path: linux/kernel/arch/arm/boot/dts/sp7021-ev.dts

Added status = ”disabled”; to node of devices.

2. Results of Measuring Temperature

 

1.2V current (mA)

Power (mW)

Temperature (°C)

Enable Display

901

1081.2

54.6

Disable Display

775

930

51.5

Reduce

126

151.2

3.1

 

1.2V current (mA)

Power (mW)

Temperature (°C)

Enable HDMI

901

1081.2

54.6

Disable HDMI

819

982.8

53.1

Reduce

82

98.4

1.5

 

 

1.2V current (mA)

Power (mW)

Temperature (°C)

 

1.2V current (mA)

Power (mW)

Temperature (°C)

Enable MIPI

901

1081.2

54.6

Disable MIPI

863

1035.6

53.9

Reduce

35

45.6

0.7

3. Modify CPIO clock and measure 1.2V/3.3V current

CPIO Clock

1.2V current (mA)

3.3V current (mA)

CPIO Clock

1.2V current (mA)

3.3V current (mA)

400M

915

109

200M

905

103

Reduce

10

6

4. Modify SYSCLK and measure 1.2V/3.3V current

SYSCLK

1.2V current (mA)

3.3V current (mA)

SYSCLK

1.2V current (mA)

3.3V current (mA)

202M

915

109

101M

723

95

Reduce

192

14